LUO Wen-sheng~1, XING Feng~2, JING Xue-wei~3, et al. Relationship between Formaldehyde Concentration of Indoor Air and Quantity of Wood-based Panels[J]. China Wood Industry, 2006,(5):24-26.
LUO Wen-sheng~1, XING Feng~2, JING Xue-wei~3, et al. Relationship between Formaldehyde Concentration of Indoor Air and Quantity of Wood-based Panels[J]. China Wood Industry, 2006,(5):24-26. DOI: 10.19455/j.mcgy.2006.05.008.
A series of experiments were conducted to evaluate how the formaldehyde concentration indoors could be affected by some environmental conditions.The factors to be tested included the formaldehyde emission of panel materials,panel setting coefficient(panel quantity to room volume),times of air exchange,and indoor temperature and humidity.Results found that under the current panel setting coefficient of 0.6 m,2,/m,3, and environmental conditions,to make the indoor formaldehyde concentration of a room attain ≤0.10 mg/m,3, or ≤0.08 mg/m,3,the formaldehyde emission of panels should be less than 0.5 mg/L and 0.3 mg/L respectively.
关键词
空气中甲醛浓度人造板甲醛释放量环境条件
Keywords
formaldehyde concentration of indoor-airwood-based panelformaldehyde emissionenvironmental condition