YIN Meng-ting, LI Bo-tao, LU Bin, et al. Detection Limits and Uncertainty of Formaldehyde Emissions from Wood-based Panels with 1 m3 Climate Chamber. [J]. China Wood Industry 33(5):34-38(2019)
YIN Meng-ting, LI Bo-tao, LU Bin, et al. Detection Limits and Uncertainty of Formaldehyde Emissions from Wood-based Panels with 1 m3 Climate Chamber. [J]. China Wood Industry 33(5):34-38(2019) DOI: 10.19455/j.mcgy.20190508.
Detection Limits and Uncertainty of Formaldehyde Emissions from Wood-based Panels with 1 m3 Climate Chamber
The 1 m,3, climate chamber method is one of the main and important tools to determine formaldehyde emissions from wood-based panels.In order to improve the accuracy of test results,the detection limits and uncertainty of the 1 m,3, climate chamber method were studies.The results showed that the detection limit of a 50 mm optical path colorimeter was not very high,which would be suitable for following formaldehyde emission tests.As for wood-based panels with low formaldehyde emissions,the uncertainty derived from duplicated measurements took a major contribution to the overall uncertainty.